The eye compares rows on both sides of a threshold, so two rooms share one grid: a common module, a joint in the doorway, a narrower cut in one of them.

A hallway 180 × 340 cm, a door out of it into a room 420 × 360 cm, and the left-hand walls of both run in one line. The same 60 × 60 cm porcelain goes in both, with a 3 mm joint, so the module is 60.3 cm. We lay the room out symmetrically: six whole tiles take 361.8 cm, and the remaining 58.2 cm splits into two strips of 29.1 cm. We start the hallway at the left-hand wall, which gives two whole rows, 120.6 cm, and a 59.4 cm cut.

Both sums are right, and each room on its own looks good. In the doorway the hallway joints miss the room joints by 29.1 cm, and that is the only place in the flat where all of it is visible at once.

The threshold shows two floors in one glance

We see a cut piece at a wall against one line only, the edge of the floor. A shifted joint in a doorway has its counterpart a few tens of centimetres further along, so the eye gets a pair of lines that were meant to be one. A few centimetres of mismatch in a doorway read worse than a narrow strip at a wall, though the strip cost more cutting.

The guide on where to start tiling puts the doorway second on its list of edges we watch, right after the wall opposite the entrance. With two rooms taking the same tile that edge moves up to first place, because it ties two layouts together at once.

We work out the shared grid before either room's starting point

The order runs opposite to the one the site imposes. We put one grid over both rooms first, then check what comes out of it at each wall separately. A starting point chosen for the room and one chosen for the hallway will almost never meet in the doorway.

In the planner we draw this as a single surface. With the add surface tool we drag the rectangle of the room, then a second one for the hallway, so that it touches the first. The two merge into one outline, the pattern lies on all of it, and the joints run through the doorway without a break.

A joint in the doorway and a tile across it are two different sums

Through the doorway we look along one axis: 340 cm of hallway plus 360 cm of room, 700 cm together. If the first tile stands with a whole edge against the wall with the front door, five rows take 301.5 cm and the sixth lands on the threshold. 38.5 cm of it stays in the hallway and 21.5 cm goes into the room. From there to the far wall 338.2 cm is left, which is five more rows and a 36.7 cm cut at the end.

The second version runs a joint right through the doorway. From the threshold towards the front door come five whole rows and 38.5 cm at the wall, and from the threshold into the room five rows and 58.5 cm at the far wall. A doorway with no tile cut across it costs us a cut piece by the front door, where a whole tile lay before.

Plan of a hallway 180 × 340 cm opening into a room 420 × 360 cm, tiled with 60 × 60 cm tiles on one grid. The grid starts with a whole tile at the wall with the front door, so the sixth row lands on the threshold.
Variant A: the threshold cuts the sixth row - 38.5 cm stays in the hallway, 21.5 cm goes into the room
The same plan with the grid shifted by 38.5 cm along the axis running through the doorway, so that a joint falls exactly on the line of the threshold.
Variant B: a joint in the doorway - a 38.5 cm strip at the front door and 58.5 cm at the far wall

A shared grid takes something away from one of the rooms

One of them gets the narrower strip at the wall, and that is the whole of the compromise. Choosing which one is a choice about visibility: behind an open door leaf, or under the shoe cupboard.

In our example the 38.5 cm by the front door goes under the doormat, and the 58.5 cm in the room reads almost like a whole tile. If the sum gave a strip narrower than half a tile, under 30 cm, we shift the whole grid and split the remainder between two walls.

A tiled floor gets its break for a different reason than laminate

Tiles bonded to the substrate do not move the way a floating floor does, and our two surfaces still will not stay in one piece. Guidelines for ceramic floor finishes give, for rooms of regular shape, a limit of 20 m² of surface without a movement joint and 5 m between joints, with field sides in a ratio up to 2:1. Our two rooms come to 21.24 m² together and 7 m along the axis through the doorway, and the L shape qualifies a floor like this for field joints on its own.

The same guidelines name door openings directly: a joint goes where door openings are designed, above all where the screeds of rooms of different sizes meet, and where floors of different thickness or construction adjoin. An intermediate joint is at least 10 mm wide, goes through the full thickness of the screed, and has to be carried through into the covering. Guides from mortar manufacturers give 5-10 mm for ceramic coverings and intermediate joints every 5-7 m indoors, a looser spacing; both figures have the status of a recommendation and differ between sources.

Carrying the joint through into the covering closes the choice from the previous section, because the movement joint runs in the line of a tile joint, so the grid has to have a joint exactly at the threshold. Underfloor heating adds a minimum of 10 mm at the perimeter joints. A 10 mm movement joint in the place of a 3 mm tile joint takes 7 mm off the first row in the room, so the last row drops from 58.5 to 57.8 cm.

Laminate in a doorway gets its break from the shape of the flat itself

Installation instructions for laminate and vinyl floors list the places where an intermediate gap is compulsory: door thresholds, passageways, L-shaped rooms, and for laminate also a length or width over 10 m. For water-resistant versions the limit moves to 15 m. Our 420 × 700 cm sits inside a 10 × 10 m field with plenty to spare, so the break here follows from the layout of the rooms alone.

The width is 8-10 mm, and on larger areas 1.5 mm per metre of floor; for a room 10 m long the instructions give 15 mm at every wall. A skirting or a profile covers the gap, and with most profiles the base goes in before the floor does. A profile in a doorway is therefore a decision from the moment before the first plank.

A change of material is a sum done on thicknesses

The 60 × 60 cm porcelain, given on the product sheet as 59.8 × 59.8 cm, is 8 mm thick. The technical datasheet for the adhesive allows a layer from 2 to 10 mm and, for a 60 × 60 cm tile on a floor, recommends a 12 mm trowel and about 3.5 kg of adhesive per square metre. A ceramic build-up therefore starts at around 10 mm and grows with the adhesive layer.

An 8 mm plank over an underlay of 1.5 to 2.0 mm gives 9.5-10 mm, and that figure does not move. With a thin bed of adhesive the two floors come out almost level; with a thicker one the tile goes up by a few millimetres.

On building forums the same piece of advice comes back: we set the screed level under each material before the pour, with about 10 mm of allowance under tiles and under laminate. After the pour only the adhesive layer or a self-levelling compound evens out the difference. Installation instructions add the door frame to this, undercut by the height of the build-up, the floor together with its underlay. The height of the threshold is a decision from the screed stage.

A threshold strip covers either the gap or just the join

With the same tile on both sides and a joint in the doorway the floor carries on without a strip, as long as no movement joint falls there. Laminate has a gap in the doorway that has to be there, which leaves the profile alone to choose.

A change of material or colour adds a difference in height to that. The smaller it is, the lower and less visible the profile, and the less the threshold gets in the way when the door leaf opens.

We draw both floors in one project

Once two rectangles merge into one surface we set the pattern in the edit pattern mode . Clicking the tile in the doorway gives its size after cutting in millimetres, so we see straight away whether the transition falls on a whole tile or on the 38.5 cm cut.

The gap in the doorway is drawn with the expansion joint tool : we pull a line and its ends run out to the walls on their own. The width goes into the settings in millimetres, so the 10 mm from the guidelines goes in there directly. A tile cut by a movement joint counts as one piece, because both of its halves go on the floor. The division adds one pattern: the first part in reading order keeps the main pattern, and the second can get its own if something else is to lie in the hallway.