← All guides

Laminate, tiles or vinyl - which one goes in which room

· 12 min read

Subfloor flatness limits, the thermal resistance of the build-up and a floor drain narrow the choice faster than colour and price per square metre.

A flat of about 33 m²: living room with kitchen 420 × 365 cm, bedroom 340 × 300 cm, bathroom 220 × 180 cm and hallway 310 × 120 cm. The living room is getting wood-effect planks 129 × 19 cm, the bathroom 60 × 60 cm porcelain, and the rest is open. The conversation in the shop ends at shade and price per square metre, because those are the only two things on display.

The materials separate on three numbers nobody in the showroom mentions: the subfloor flatness allowed, the thermal resistance of everything above the heating pipes, and the hours of water resistance. Each of them rules out one material in one particular room, before the question of colour comes up at all.

Three kinds of wetting split the flat into zones

A spilled glass, the humidity after a bath and water standing on the floor are three different loads, and each material answers them with a different kind of declaration.

Moisture-protected laminate gets a number of hours. Declarations reach 24 hours for ordinary cores and 72 hours for cores formulated against swelling, and the figure covers water standing on the surface and then wiped up, not permanent damp from below. Sealing tape and water-resistant skirtings come with it, and without them the declaration does not hold.

Click vinyl copes with humid rooms, but the installation instructions for rigid click panels rule out rooms with a floor drain outright, along with shower trays, pool surrounds, saunas and unheated rooms. A drain in the floor closes the question of vinyl in this bathroom, water-resistant though the material is.

Tiles are sorted by water absorption, and EN 14411 describes the groups. Group BIa porcelain absorbs under 0.5 percent, is frost-resistant and goes anywhere, a shower floor included. Group BIII glazed tile absorbs over 10 percent, is not frost-resistant and goes on indoor walls only. The same shelf holds a product for the terrace next to a product that will last one winter on it. Falls, the drain and slip resistance from R9 to R13 get their own guide: bathroom tile layout.

A use class describes the room, not the quality of the product

The number on a pack of laminate comes from the classification in EN 13329, built on EN 685. The first digit says what kind of building: 2 is a home, 3 a public building, 4 industry; the second describes the traffic within that group. A bedroom sits in class 21, a hallway in 23, and class 31 describes a hotel room or a conference room.

Some manufacturers put their whole laminate range in classes 31, 32 and 33, which is to say they start where the domestic scale ends. A class 32 plank in our bedroom works far below what it was built for, and we pay for a reserve that will never be used up.

The wear of the top layer alone is a separate marking: AC1 to AC6, from the Taber test. Vinyl states its wear layer in millimetres, where 0.30 mm answers domestic use and 0.55 mm is already classified by manufacturers to class 33 and 42. Glazed porcelain has a PEI class, quoted with a number of revolutions, from 600 for PEI 2 to over 12,000 for PEI 5. Three materials, then, described by five different scales, and none of them converts into the others.

Glued vinyl needs a subfloor five times flatter than laminate

Subfloor tolerances are split by method of installation rather than by material. Floating laminate and rigid click vinyl allow 4 mm of unevenness under a two-metre straightedge and 1 mm under a 20 cm one. Thin vinyl glued to the subfloor comes down to 3 mm under two metres and 0.2 mm under 20 cm.

That 0.2 mm is the thickness of two sheets of paper. A thin, flexible material bonded over its whole area reproduces every grain of screed, while a rigid board with a click joint passes over it leaving nothing. So the cost of a self-levelling compound belongs on the bill for glued vinyl.

Tile has no such number, because the bed of adhesive absorbs small irregularities. Tiling instructions call for checking the level of the subfloor and correcting it with self-levelling compound, and for large formats additionally for tile levelling systems, which take out both the unevenness of the subfloor and the curvature of the tile itself. The order of the costs reverses against the price of the material here: the cheapest covering to buy makes the most expensive demands on the screed.

Underfloor heating is settled in thermal resistance

For floating floors the instructions set two conditions: no more than 27 °C at the surface, and the sum of the thermal resistances of every layer above the heating system no greater than 0.15 m²K/W.

In the worked example from those same instructions an 8 mm plank has a resistance of 0.055 m²K/W and the underlay beneath it 0.045. Together they take 0.100 of the 0.15 budget, two thirds of it. A 10 mm ceramic tile in the same calculation has 0.010 m²K/W, at a greater thickness. In our living room with underfloor heating, porcelain leaves room for the remaining layers, while with laminate the choice of underlay stops being free. Vinyl glued over its whole area transfers heat best of the wood-effect floors, and the instructions say so outright.

Commissioning has rules common to all three materials: the heating goes on at least two weeks before laying, and the temperature rises by no more than 5 °C a day. A cement screed under heating has to come down to 1.5 percent CM moisture, against the 2.5 percent allowed without it. With tiles comes switching the heating off 24 hours before work starts and back on only once the adhesive has gained full strength. This schedule cannot be made up for once the floor is finished.

A floating floor will not carry kitchen units

Laminate and click vinyl lie loose and move with temperature. The instructions require 8 mm of expansion gap round the entire perimeter, around pipes and around every fixed element, and an uninterrupted field may run to 13 × 13 m in typical domestic conditions of 15 to 35 °C. A T-profile in the doorway becomes mandatory with separate heating zones, with an L-, U- or T-shaped room, and where the permitted field is exceeded. Our living room joined to the hallway meets two of those conditions at once.

The condition that overturns a kitchen design sits in a footnote to that same tolerance table. Heavy and fixed objects, which is to say base units, the island, the cooker and the wardrobe, have to stand directly on the subfloor. A floating floor that is pinned down has nowhere to expand and buckles somewhere else instead. If the units must stand on the covering after all, manufacturers point to a fully bonded installation. On the forums the same matter comes back as a voided warranty and holes cut for furniture legs.

The order of work changes then: the units go in first and the floor runs up to their plinth. Tile bonded to the subfloor does not know this restriction, and it is a real advantage for porcelain in a kitchen, independent of water. Skirtings in both cases are fixed to the wall, never to the floor.

The last row works out the same way for a plank and for a tile

A 129 × 19 cm plank in the 420 × 365 cm living room. Take 8 mm of expansion gap off both sides and 363.4 cm is left for rows of 19 cm. Nineteen whole rows take 361 cm and 2.4 cm is left for the last. Laminate manufacturers give 5 cm as the minimum width of the last row, so that strip is out of the question.

The way out is the same as with tiles: cut the first row as well. Eighteen rows come to 342 cm, the remaining 21.4 cm splits in two, and 10.7 cm falls at each wall. Both clear the manufacturer's requirement.

A 420 × 365 cm living room with 129 × 19 cm planks laid from the wall: nineteen whole rows and a 2.4 cm strip along the opposite wall
First plank against the spacers
The same living room with the first row cut down: eighteen whole rows and two outer rows of 10.7 cm
First and last row at 10.7 cm

The same arithmetic handles 60 × 60 cm porcelain with a 3 mm joint, only the module comes to 60.3 cm. The planner takes the size of the piece and the width of the joint, and the pattern editing tool gives the size of an edge piece after cutting when it is clicked. The perimeter expansion gap is a field of its own on the pattern, in millimetres: enter 8 mm and the covering stops 8 mm short of every wall, leaving the band beside it bare. Cut pieces are then worked out from a field of 418.4 × 363.4 cm. The tile count comes to the same forty-nine, but twenty-four are cut instead of thirteen. Gaps through the middle of the surface are drawn with the tool, which runs a line from wall to wall: that is the T-profile in a doorway and the division of a tiled floor required every 9-16 m². The number of pieces, the number of cuts and the waste come before the choice of material, so three options can be compared on the drawing. What stays outside it is the floor drain and the thermal resistance of the underlay.

What this comes to for this flat

The bathroom with a floor drain stays with BIa porcelain, because click vinyl is ruled out there by the instructions and laminate has a resistance counted in hours. The living room with the kitchen and underfloor heating also points to tile, decided by thermal resistance together with the units, which cannot stand on a floating floor. In the bedroom and the hallway none of those restrictions applies, so what settles it is the use class and the things the datasheets do not state.

On the forums three observations come back at this point. Vinyl is quiet underfoot, laminate drums. After two or three years vinyl shows micro-scratches where chairs are pushed about. Porcelain is cold underfoot until there is heating beneath it. None of them carries a standard number, and in a bedroom they settle more than class 32 does.

The road from an empty room to a drawing in scale is set out in planning a floor with the planner, the slips in the layout itself are gathered in tile layout planning mistakes, and counting material for laminate has a text of its own: how much laminate flooring to buy.

Where these numbers come from